SV Microwave has released a new line of RF connectors for Ø.047" cable that features an extended-length ferrule to protect the solder joints and fragile cable sections from environmental stress. This cable connector product line includes threaded male SMA, 2.92mm, and 2.4mm configurations and female push-on SMP and SMPM configurations.
Features / Benefits:
Applications:
Impedance (Ω) | 50 |
Frequency GHz | 50 GHz |
Shielding Effectiveness | ≥ -100 dB |
Dielectric withstanding Voltage | 500 VRMS |
Mating Cycles | 500 |
Mating Torque | 5 - 7 in - lbs |
Inter-mate ability | 1.85mm |
Temperature Rating | -65°C to +165°C |
Corrosion (salt spray) | MIL-STD-202, Method 101, Condition B |
Vibration | MIL-STD-202, Method 204, Condition D |
Shock | MIL-STD-202, Method 213, Condition I |
Thermal Shock | MIL-STD-202, Method 107, Condition B |
Moisture Resistance | MIL-STD-202, Method 106, Less Step 7B |
Barometric Pressure (Altitude) | MIL-STD-202, Method 105, Condition C, 70k Ft. |
Impedance (Ω) | 50 |
Frequency GHz | 40 GHz |
Shielding Effectiveness | ≥ -100 dB |
Dielectric withstanding Voltage | 750 VRMS |
Mating Cycles | 500 |
Mating Torque | 7 - 10 in - lbs |
Inter-mate ability | SMA |
Temperature Rating | -65°C to +165°C |
Corrosion (salt spray) | MIL-STD-202, Method 101, Condition B |
Vibration | MIL-STD-202, Method 204, Condition D |
Shock | MIL-STD-202, Method 213, Condition I |
Thermal Shock | MIL-STD-202, Method 107, Condition B |
Moisture Resistance | MIL-STD-202, Method 106, Less Step 7B |
Barometric Pressure (Altitude) | MIL-STD-202, Method 105, Condition C, 70k Ft. |
Impedance (Ω) | 50 |
Frequency GHz | 18 GHz (select models to 26.5 GHz) |
Shielding Effectiveness | ≥ -90 dB |
Dielectric withstanding Voltage | 1000 VRMS |
Mating Cycles | 500 |
Mating Torque | 7 - 10 in - lbs |
Inter-mate ability | 2.92mm |
Temperature Rating | -65°C to +165°C |
Corrosion (salt spray) | MIL-STD-202, Method 101, Condition B |
Vibration | MIL-STD-202, Method 204, Condition D |
Shock | MIL-STD-202, Method 213, Condition I |
Thermal Shock | MIL-STD-202, Method 107, Condition B |
Moisture Resistance | MIL-STD-202, Method 106, Less Step 7B |
Barometric Pressure (Altitude) | MIL-STD-202, Method 105, Condition C, 70k Ft. |
Impedance (Ω) | 50 |
Frequency GHz | 40 GHz |
Shielding Effectiveness | ≥ -80 dB DC - 3 GHz ≥ -65 dB 3 - 26.5 GHz |
Dielectric withstanding Voltage | 500 VRMS |
Mating Cycles - SB | 1000 |
Mating Cycles - LD | 500 |
Mating Cycles - FD | 100 |
Insertion Force - SB | 3.0 lbs |
Insertion Force - LD | 5.0 lbs |
Insertion Force - FD | 7.0 lbs |
Withdrawal Force - SB | 0.5 lbs |
Withdrawal Force - LD | 7.0 lbs |
Withdrawal Force - FD | 9.0 lbs |
Axial Misalignment | .010” Max |
Radial Misalignment | 3° Max |
Temperature Rating | -65°C to +165°C |
Corrosion (salt spray) | MIL-STD-202, Method 101, Condition B |
Vibration | MIL-STD-202, Method 204, Condition D |
Shock | MIL-STD-202, Method 213, Condition I |
Thermal Shock | MIL-STD-202, Method 107, Condition B |
Moisture Resistance | MIL-STD-202, Method 106, Less Step 7B |
Barometric Pressure (Altitude) | MIL-STD-202, Method 105, Condition C, 70k Ft. |
Impedance (Ω) | 50 |
Frequency GHz | 65 GHz |
Shielding Effectiveness | ≥ -80 dB DC - 3 GHz ≥ -65 dB 3 - 26.5 GHz |
Dielectric withstanding Voltage | 325 VRMS |
Mating Cycles - SB | 500 |
Mating Cycles - FD | 100 |
Insertion Force - SB | 2.5 lbs |
Insertion Force - FD | 4.5 lbs |
Withdrawal Force - SB | 1.5 lbs |
Withdrawal Force - FD | 6.5 lbs |
Axial Misalignment | .010” Max |
Radial Misalignment | 3° Max |
Temperature Rating | -65°C to +165°C |
Corrosion (salt spray) | MIL-STD-202, Method 101, Condition B |
Vibration | MIL-STD-202, Method 204, Condition D |
Shock | MIL-STD-202, Method 213, Condition I |
Thermal Shock | MIL-STD-202, Method 107, Condition B |
Moisture Resistance | MIL-STD-202, Method 106, Less Step 7B |
Barometric Pressure (Altitude) | MIL-STD-202, Method 105, Condition C, 70k Ft. |