SV Microwave offers fixed-length RF cable assemblies using its extremely pliable SuperFlex Ø.047" cable. SV's SuperFlex product line includes right angle and straight SMP and SMPM connectors for unmatched routing in tight spaces.
This super flexible coax cable is capable of extreme bends, which allow it to fit in tight spaces and route for any application. Available in series: SMP, SMPM and SMA. Various lengths available: 3", 6", and 12".
Features / Benefits:
Applications:
Impedance (Ω) | 50 |
Frequency GHz | 40 GHz |
Shielding Effectiveness | ≥ -100 dB |
Dielectric withstanding Voltage | 750 VRMS |
Mating Cycles | 500 |
Mating Torque | 7 - 10 in - lbs |
Inter-mate ability | SMA |
Temperature Rating | -65°C to +165°C |
Corrosion (salt spray) | MIL-STD-202, Method 101, Condition B |
Vibration | MIL-STD-202, Method 204, Condition D |
Shock | MIL-STD-202, Method 213, Condition I |
Thermal Shock | MIL-STD-202, Method 107, Condition B |
Moisture Resistance | MIL-STD-202, Method 106, Less Step 7B |
Barometric Pressure (Altitude) | MIL-STD-202, Method 105, Condition C, 70k Ft. |
Impedance (Ω) | 50 |
Frequency GHz | 18 GHz (select models to 26.5 GHz) |
Shielding Effectiveness | ≥ -90 dB |
Dielectric withstanding Voltage | 1000 VRMS |
Mating Cycles | 500 |
Mating Torque | 7 - 10 in - lbs |
Inter-mate ability | 2.92mm |
Temperature Rating | -65°C to +165°C |
Corrosion (salt spray) | MIL-STD-202, Method 101, Condition B |
Vibration | MIL-STD-202, Method 204, Condition D |
Shock | MIL-STD-202, Method 213, Condition I |
Thermal Shock | MIL-STD-202, Method 107, Condition B |
Moisture Resistance | MIL-STD-202, Method 106, Less Step 7B |
Barometric Pressure (Altitude) | MIL-STD-202, Method 105, Condition C, 70k Ft. |
Impedance (Ω) | 50 |
Frequency GHz | 40 GHz |
Shielding Effectiveness | ≥ -80 dB DC - 3 GHz ≥ -65 dB 3 - 26.5 GHz |
Dielectric withstanding Voltage | 500 VRMS |
Mating Cycles - SB | 1000 |
Mating Cycles - LD | 500 |
Mating Cycles - FD | 100 |
Insertion Force - SB | 3.0 lbs |
Insertion Force - LD | 5.0 lbs |
Insertion Force - FD | 7.0 lbs |
Withdrawal Force - SB | 0.5 lbs |
Withdrawal Force - LD | 7.0 lbs |
Withdrawal Force - FD | 9.0 lbs |
Axial Misalignment | .010” Max |
Radial Misalignment | 3° Max |
Temperature Rating | -65°C to +165°C |
Corrosion (salt spray) | MIL-STD-202, Method 101, Condition B |
Vibration | MIL-STD-202, Method 204, Condition D |
Shock | MIL-STD-202, Method 213, Condition I |
Thermal Shock | MIL-STD-202, Method 107, Condition B |
Moisture Resistance | MIL-STD-202, Method 106, Less Step 7B |
Barometric Pressure (Altitude) | MIL-STD-202, Method 105, Condition C, 70k Ft. |
Impedance (Ω) | 50 |
Frequency GHz | 65 GHz |
Shielding Effectiveness | ≥ -80 dB DC - 3 GHz ≥ -65 dB 3 - 26.5 GHz |
Dielectric withstanding Voltage | 325 VRMS |
Mating Cycles - SB | 500 |
Mating Cycles - FD | 100 |
Insertion Force - SB | 2.5 lbs |
Insertion Force - FD | 4.5 lbs |
Withdrawal Force - SB | 1.5 lbs |
Withdrawal Force - FD | 6.5 lbs |
Axial Misalignment | .010” Max |
Radial Misalignment | 3° Max |
Temperature Rating | -65°C to +165°C |
Corrosion (salt spray) | MIL-STD-202, Method 101, Condition B |
Vibration | MIL-STD-202, Method 204, Condition D |
Shock | MIL-STD-202, Method 213, Condition I |
Thermal Shock | MIL-STD-202, Method 107, Condition B |
Moisture Resistance | MIL-STD-202, Method 106, Less Step 7B |
Barometric Pressure (Altitude) | MIL-STD-202, Method 105, Condition C, 70k Ft. |