SV Microwave offers DC to 65 GHz high frequency size 8, 12 and 16 coaxial contacts for the D38999 Series III housing and standard inserts. These contacts allow any application to continue to use the D38999 connector and be able to expand the use to include the microwave transmission lines.
Features / Benefits:
Applications:
Impedance (Ω) | 50 |
Frequency GHz | 18 GHz |
Shielding Effectiveness | ≥ -90 dB |
Dielectric withstanding Voltage | 1000 VRMS |
Mating Cycles | 5000 |
Insertion Force | 3.0 lbs |
Withdrawal Force | 1.5 lbs |
Temperature Rating | -65°C to +165°C |
Corrosion (salt spray) | MIL-STD-202, Method 101, Condition B |
Vibration | MIL-STD-202, Method 204, Condition D |
Shock | MIL-STD-202, Method 213, Condition I |
Thermal Shock | MIL-STD-202, Method 107, Condition B |
Moisture Resistance | MIL-STD-202, Method 106, Less Step 7B |
Barometric Pressure (Altitude) | MIL-STD-202, Method 105, Condition C, 70k Ft. |
Impedance (Ω) | 50 |
Frequency GHz | 18 GHz |
Shielding Effectiveness | ≥ -80 dB |
Dielectric withstanding Voltage | 1000 VRMS |
Mating Cycles | 500 |
Insertion Force | 0.75 lbs |
Withdrawal Force | 0.13 lbs |
Temperature Rating | -65°C to +165°C |
Corrosion (salt spray) | MIL-STD-202, Method 101, Condition B |
Vibration | MIL-STD-202, Method 204, Condition D |
Shock | MIL-STD-202, Method 213, Condition I |
Thermal Shock | MIL-STD-202, Method 107, Condition B |
Moisture Resistance | MIL-STD-202, Method 106, Less Step 7B |
Barometric Pressure (Altitude) | MIL-STD-202, Method 105, Condition C, 70k Ft. |
Impedance (Ω) | 50 |
Frequency GHz | 40 GHz |
Corrosion (salt spray) | MIL-STD-202, Method 101, Condition B |
Vibration | MIL-STD-202, Method 204, Condition D |
Shock | MIL-STD-202, Method 213, Condition I |
Thermal Shock | MIL-STD-202, Method 107, Condition B |
Moisture Resistance | MIL-STD-202, Method 106, Less Step 7B |
Barometric Pressure (Altitude) | MIL-STD-202, Method 105, Condition C, 70k Ft. |
Impedance (Ω) | 50 |
Frequency GHz | 65 GHz |
Shielding Effectiveness | ≥ -80 dB DC - 3 GHz ≥ -65 dB 3 - 26.5 GHz |
Dielectric withstanding Voltage | 325 VRMS |
Mating Cycles - SB | 500 |
Mating Cycles - FD | 100 |
Insertion Force - SB | 2.5 lbs |
Insertion Force - FD | 4.5 lbs |
Withdrawal Force - SB | 1.5 lbs |
Withdrawal Force - FD | 6.5 lbs |
Axial Misalignment | .010” Max |
Radial Misalignment | 3° Max |
Temperature Rating | -65°C to +165°C |
Corrosion (salt spray) | MIL-STD-202, Method 101, Condition B |
Vibration | MIL-STD-202, Method 204, Condition D |
Shock | MIL-STD-202, Method 213, Condition I |
Thermal Shock | MIL-STD-202, Method 107, Condition B |
Moisture Resistance | MIL-STD-202, Method 106, Less Step 7B |
Barometric Pressure (Altitude) | MIL-STD-202, Method 105, Condition C, 70k Ft. |
Impedance (Ω) | 50 |
Frequency GHz | 65 GHz |
Shielding Effectiveness | ≥ -80 dB DC - 3 GHz ≥ -65 dB 3 - 26.5 GHz |
Dielectric withstanding Voltage | 250 VRMS |
Mating Cycles - SB | 500 |
Mating Cycles - FD | 100 |
Insertion Force - SB | 1.2 lbs |
Insertion Force - FD | 2.5 lbs |
Withdrawal Force - SB | 1.0 lbs |
Withdrawal Force - FD | 4.5 lbs |
Axial Misalignment | .010” Max |
Radial Misalignment | 3° Max |
Temperature Rating | -65°C to +165°C |
Corrosion (salt spray) | MIL-STD-202, Method 101, Condition B |
Vibration | MIL-STD-202, Method 204, Condition D |
Shock | MIL-STD-202, Method 213, Condition I |
Thermal Shock | MIL-STD-202, Method 107, Condition B |
Moisture Resistance | MIL-STD-202, Method 106, Less Step 7B |
Barometric Pressure (Altitude) | MIL-STD-202, Method 105, Condition C, 70k Ft. |