Extended Ferrule RF Cable Connectors

Picture for category Extended Ferrule RF Cable Connectors

SV Microwave has released a new line of RF connectors for Ø.047" cable that features an extended-length ferrule to protect the solder joints and fragile cable sections from environmental stress. This cable connector product line is more durable and includes threaded male SMA, 2.92mm, and 2.4mm configurations and female push-on SMP and SMPM configurations. 

Features / Benefits: 

  • Longer-length ferrule protects solder joints and the most fragile sections of cable assemblies
  • Increases durability for use in the field
  • Replaces the need for shrink tubing
  • Allows aggressive bends 

Applications:

  • Military and Aerospace
  • Test and Instrumentation
  • Industrial

2.4 mm

 Impedance (Ω)  50
 Frequency GHz  50 GHz
 Shielding Effectiveness  ≥ -100 dB
 Dielectric withstanding Voltage  500 VRMS
 Mating Cycles  500
 Mating Torque  5 - 7 in - lbs
 Inter-mate ability  1.85mm
 Temperature Rating  -65°C to +165°C
 Corrosion (salt spray)  MIL-STD-202, Method 101, Condition B
 Vibration  MIL-STD-202, Method 204, Condition D
 Shock  MIL-STD-202, Method 213, Condition I
 Thermal Shock  MIL-STD-202, Method 107, Condition B
 Moisture Resistance  MIL-STD-202, Method 106, Less Step 7B
 Barometric Pressure (Altitude)  MIL-STD-202, Method 105, Condition C, 70k Ft.

 

2.92 mm

 Impedance (Ω)  50
 Frequency GHz  40 GHz
 Shielding Effectiveness  ≥ -100 dB
 Dielectric withstanding Voltage  750 VRMS
 Mating Cycles  500
 Mating Torque  7 - 10 in - lbs
 Inter-mate ability  SMA
 Temperature Rating  -65°C to +165°C
 Corrosion (salt spray)  MIL-STD-202, Method 101, Condition B
 Vibration  MIL-STD-202, Method 204, Condition D
 Shock  MIL-STD-202, Method 213, Condition I
 Thermal Shock  MIL-STD-202, Method 107, Condition B
 Moisture Resistance  MIL-STD-202, Method 106, Less Step 7B
 Barometric Pressure (Altitude)  MIL-STD-202, Method 105, Condition C, 70k Ft.

 

SMA

 Impedance (Ω)  50
 Frequency GHz  18 GHz (select models to 26.5 GHz)
 Shielding Effectiveness  ≥ -90 dB
 Dielectric withstanding Voltage  1000 VRMS
 Mating Cycles  500
 Mating Torque  7 - 10 in - lbs
 Inter-mate ability  2.92mm
 Temperature Rating  -65°C to +165°C
 Corrosion (salt spray)  MIL-STD-202, Method 101, Condition B
 Vibration  MIL-STD-202, Method 204, Condition D
 Shock  MIL-STD-202, Method 213, Condition I
 Thermal Shock  MIL-STD-202, Method 107, Condition B
 Moisture Resistance  MIL-STD-202, Method 106, Less Step 7B
 Barometric Pressure (Altitude)  MIL-STD-202, Method 105, Condition C, 70k Ft.

 

SMP

 Impedance (Ω)  50
 Frequency GHz  40 GHz
 Shielding Effectiveness  ≥ -80 dB DC - 3 GHz
 ≥ -65 dB 3 - 26.5 GHz
 Dielectric withstanding Voltage  500 VRMS
 Mating Cycles - SB   1000
 Mating Cycles - LD  500
 Mating Cycles - FD   100
 Insertion Force - SB  3.0 lbs
 Insertion Force - LD  5.0 lbs
 Insertion Force - FD   7.0 lbs
 Withdrawal Force - SB  0.5 lbs
 Withdrawal Force - LD  7.0 lbs
  Withdrawal Force - FD   9.0 lbs
 Axial Misalignment  .010” Max
 Radial Misalignment  3° Max
 Temperature Rating  -65°C to +165°C
 Corrosion (salt spray)  MIL-STD-202, Method 101, Condition B
 Vibration  MIL-STD-202, Method 204, Condition D
 Shock  MIL-STD-202, Method 213, Condition I
 Thermal Shock  MIL-STD-202, Method 107, Condition B
 Moisture Resistance  MIL-STD-202, Method 106, Less Step 7B
 Barometric Pressure (Altitude)  MIL-STD-202, Method 105, Condition C, 70k Ft.

 

SMPM

 Impedance (Ω)  50
 Frequency GHz  65 GHz
 Shielding Effectiveness  ≥ -80 dB DC - 3 GHz
 ≥ -65 dB 3 - 26.5 GHz
 Dielectric withstanding Voltage  325 VRMS
 Mating Cycles - SB   500
 Mating Cycles - FD   100
 Insertion Force - SB  2.5 lbs
 Insertion Force - FD   4.5 lbs
 Withdrawal Force - SB  1.5 lbs
 Withdrawal Force - FD   6.5 lbs
 Axial Misalignment  .010” Max
 Radial Misalignment  3° Max
 Temperature Rating  -65°C to +165°C
 Corrosion (salt spray)  MIL-STD-202, Method 101, Condition B
 Vibration  MIL-STD-202, Method 204, Condition D
 Shock  MIL-STD-202, Method 213, Condition I
 Thermal Shock  MIL-STD-202, Method 107, Condition B
 Moisture Resistance  MIL-STD-202, Method 106, Less Step 7B
 Barometric Pressure (Altitude)  MIL-STD-202, Method 105, Condition C, 70k Ft.
Filters
Part #   1611-60028

2.4mm Male Connector, Extended Ferrule for .047 Cable

Available Inventory: 113
1611-60028
2.4mm Connectors 1611-60028
Datasheet
Part #   1511-60133

2.92mm Male Connector, Extended Ferrule for .047 Cable

Available Inventory: 125
1511-60133
2.92mm Connectors 1511-60133
Datasheet
Part #   2911-61016

SMA Male Connector, Extended Ferrule for .047 Cable

Available Inventory: 125
2911-61016
SMA Connectors 2911-61016
Datasheet
Part #   1221-40115

SMP Female Connector, Extended Ferrule for .047 Cable

Available Inventory: 25
1221-40115
SMP Connectors 1221-40115
Datasheet
Part #   3221-40147

SMPM Female Connector, Extended Ferrule for .047 Cable

Available Inventory: 125
3221-40147
SMPM Connectors 3221-40147
Datasheet
Filters Clear All