SV Microwave’s high speed RF/coaxial solderless compression mount connectors are ideal for high frequency printed circuit board applications where precision is key. Our solderless application makes assembly fast, easy and without damaging the PCB board. Current interface configurations include our high frequency SMA, 2.92mm, 2.4mm, 1.85mm, SMP and SMPM series.
Features / Benefits:
Applications:
Impedance (Ω) | 50 |
Frequency GHz | 50 GHz |
Shielding Effectiveness | ≥ -100 dB |
Dielectric withstanding Voltage | 500 VRMS |
Mating Cycles | 500 |
Mating Torque | 5 - 7 in - lbs |
Inter-mate ability | 1.85mm |
Temperature Rating | -65°C to +165°C |
Corrosion (salt spray) | MIL-STD-202, Method 101, Condition B |
Vibration | MIL-STD-202, Method 204, Condition D |
Shock | MIL-STD-202, Method 213, Condition I |
Thermal Shock | MIL-STD-202, Method 107, Condition B |
Moisture Resistance | MIL-STD-202, Method 106, Less Step 7B |
Barometric Pressure (Altitude) | MIL-STD-202, Method 105, Condition C, 70k Ft. |
Impedance (Ω) | 50 |
Frequency GHz | 40 GHz |
Shielding Effectiveness | ≥ -100 dB |
Dielectric withstanding Voltage | 750 VRMS |
Mating Cycles | 500 |
Mating Torque | 7 - 10 in - lbs |
Inter-mate ability | SMA |
Temperature Rating | -65°C to +165°C |
Corrosion (salt spray) | MIL-STD-202, Method 101, Condition B |
Vibration | MIL-STD-202, Method 204, Condition D |
Shock | MIL-STD-202, Method 213, Condition I |
Thermal Shock | MIL-STD-202, Method 107, Condition B |
Moisture Resistance | MIL-STD-202, Method 106, Less Step 7B |
Barometric Pressure (Altitude) | MIL-STD-202, Method 105, Condition C, 70k Ft. |
Impedance (Ω) | 50 |
Frequency GHz | 18 GHz (select models to 26.5 GHz) |
Shielding Effectiveness | ≥ -90 dB |
Dielectric withstanding Voltage | 1000 VRMS |
Mating Cycles | 500 |
Mating Torque | 7 - 10 in - lbs |
Inter-mate ability | 2.92mm |
Temperature Rating | -65°C to +165°C |
Corrosion (salt spray) | MIL-STD-202, Method 101, Condition B |
Vibration | MIL-STD-202, Method 204, Condition D |
Shock | MIL-STD-202, Method 213, Condition I |
Thermal Shock | MIL-STD-202, Method 107, Condition B |
Moisture Resistance | MIL-STD-202, Method 106, Less Step 7B |
Barometric Pressure (Altitude) | MIL-STD-202, Method 105, Condition C, 70k Ft. |
Impedance (Ω) | 50 |
Frequency GHz | 40 GHz |
Shielding Effectiveness | ≥ -80 dB DC - 3 GHz ≥ -65 dB 3 - 26.5 GHz |
Dielectric withstanding Voltage | 500 VRMS |
Mating Cycles - SB | 1000 |
Mating Cycles - LD | 500 |
Mating Cycles - FD | 100 |
Insertion Force - SB | 3.0 lbs |
Insertion Force - LD | 5.0 lbs |
Insertion Force - FD | 7.0 lbs |
Withdrawal Force - SB | 0.5 lbs |
Withdrawal Force - LD | 7.0 lbs |
Withdrawal Force - FD | 9.0 lbs |
Axial Misalignment | .010” Max |
Radial Misalignment | 3° Max |
Temperature Rating | -65°C to +165°C |
Corrosion (salt spray) | MIL-STD-202, Method 101, Condition B |
Vibration | MIL-STD-202, Method 204, Condition D |
Shock | MIL-STD-202, Method 213, Condition I |
Thermal Shock | MIL-STD-202, Method 107, Condition B |
Moisture Resistance | MIL-STD-202, Method 106, Less Step 7B |
Barometric Pressure (Altitude) | MIL-STD-202, Method 105, Condition C, 70k Ft. |
Impedance (Ω) | 50 |
Frequency GHz | 65 GHz |
Shielding Effectiveness | ≥ -80 dB DC - 3 GHz ≥ -65 dB 3 - 26.5 GHz |
Dielectric withstanding Voltage | 325 VRMS |
Mating Cycles - SB | 500 |
Mating Cycles - FD | 100 |
Insertion Force - SB | 2.5 lbs |
Insertion Force - FD | 4.5 lbs |
Withdrawal Force - SB | 1.5 lbs |
Withdrawal Force - FD | 6.5 lbs |
Axial Misalignment | .010” Max |
Radial Misalignment | 3° Max |
Temperature Rating | -65°C to +165°C |
Corrosion (salt spray) | MIL-STD-202, Method 101, Condition B |
Vibration | MIL-STD-202, Method 204, Condition D |
Shock | MIL-STD-202, Method 213, Condition I |
Thermal Shock | MIL-STD-202, Method 107, Condition B |
Moisture Resistance | MIL-STD-202, Method 106, Less Step 7B |
Barometric Pressure (Altitude) | MIL-STD-202, Method 105, Condition C, 70k Ft. |