Embedded System applications are commonly used to provide modular solutions that transition from inside-of-the-box to outside-of-the-box applications. SV’s newest fixed-length RF cable assemblies allow you to expand the use of the standard D38999 circular connector to incorporate microwave transmission lines. These assemblies are available in VITA 67.3 SMPM, SMPS, and NanoRF series and terminate into various D38999 BMB, SMPM, and SMPS interfaces and their respective size 8, 12, and 16 contacts. These assemblies' contacts meet the latest SOSA™ specifications and can fit D38999 series I, III, and IV housings.
Features / Benefits:
Applications:
Impedance (Ω) | 50 |
Frequency GHz | 40 GHz |
Shielding Effectiveness | ≥ -100 dB, DC to 26.5 GHz |
Dielectric withstanding Voltage | 325 VRMS |
Mating Cycles | 500 |
Insertion Force | 2.5 lbs (per contact) |
Withdrawal Force | 1.5 lbs |
Temperature Rating | -65°C to +165°C |
Corrosion (salt spray) | MIL-STD-202, Method 101, Condition B |
Vibration | MIL-STD-202, Method 204, Condition D |
Shock | MIL-STD-202, Method 213, Condition I |
Thermal Shock | MIL-STD-202, Method 107, Condition B |
Moisture Resistance | MIL-STD-202, Method 106, Less Step 7B |
Barometric Pressure (Altitude) | MIL-STD-202, Method 105, Condition C, 70k Ft. |
Impedance (Ω) | 50 |
Frequency GHz | 65 GHz |
Shielding Effectiveness | ≥ -100 dB, DC to 26.5 GHz |
Dielectric withstanding Voltage | 250 VRMS |
Mating Cycles | 500 |
Insertion Force | 1.2 lbs (per contact) |
Withdrawal Force | 1.0 lbs |
Temperature Rating | -65°C to +165°C |
Corrosion (salt spray) | MIL-STD-202, Method 101, Condition B |
Vibration | MIL-STD-202, Method 204, Condition D |
Shock | MIL-STD-202, Method 213, Condition I |
Thermal Shock | MIL-STD-202, Method 107, Condition B |
Moisture Resistance | MIL-STD-202, Method 106, Less Step 7B |
Barometric Pressure (Altitude) | MIL-STD-202, Method 105, Condition C, 70k Ft. |
Impedance (Ω) | 50 |
Frequency GHz | 67 GHz |
Shielding Effectiveness | ≥ -140 dB, 3 MHz to 30 MHz ≥ -120 dB, 30 MHz to 3.0 GHz ≥ -100 dB, 3.0 GHz to 30 GHz ≥ -90 dB, 30 to 67.0 GHz |
Dielectric withstanding Voltage | 250 VRMS |
Mating Cycles | 500 |
Insertion Force | 2.5 lbs (per contact) |
Withdrawal Force | 0.315 lbs |
Temperature Rating | -55°C to +125°C |
Corrosion (salt spray) | MIL-STD-202, Method 101, Condition B |
Vibration | MIL-STD-202, Method 204, Condition D |
Shock | MIL-STD-202, Method 213, Condition I |
Thermal Shock | MIL-STD-202, Method 107, Condition B |
Moisture Resistance | MIL-STD-202, Method 106, Less Step 7B |
Barometric Pressure (Altitude) | MIL-STD-202, Method 105, Condition C, 70k Ft. |